FIRE PUMP


Fire fighting

Fire fighting

Hydrant

Hydrant



Fire Water Systems

Fire Water Systems

Head

Head

Jockey Compound Gauge Fire Pump Pressure Diesel Fuel Tank

Jockey Compound Gauge Fire Pump Pressure Diesel Fuel Tank

Horizontal Fire Water Pumps

Horizontal Fire Water Pumps

Vertical Turbine Fire Water Pumps

Vertical Turbine Fire Water Pumps

Fire Water Pump Project

Centrifugal Fire Water Pump Project

Fire Pump Project

Fire Pump Project

Fire Water Pumps

Fire Water Pumps

Fire Water Pumps

Fire Water Pumps

Fire Water Pumps

Fire Water Pumps

Fire Water Pump

Fire Water Pump

Fire Pump

Diesel Engine Fire Pump Controller

Fire Water Electric Jockey Pump

Fire Water Electric Jockey Pump

UL FM Listed NFPA 20 bahtiar@gmail.com

UL FM Listed NFPA 20 bahtiar@gmail.com

We provide :
HORIZONTAL SPLIT CASE FIRE PUMP SYSTEM DIESEL ENGINE DRIVEN Fuel Tank Diesel Engine Isolation Gate Valve (suction) Compound Suction Gauge Automatic Air Release Valve Diesel Engine Drive Horizontal Split Case Fire Pump Discharge Pressure Gauge Enclosed Waste Cone with Sight Glasses Main Relief Valve Low Suction Pressure Shutoff Valve Fire Pump Controller System Check Valve Jockey Pump Controller Jockey Pump Isolation Valves Ball Drip Valve Test Valve Manifold with Hose Valves Caps & Chains Pump Horizontal split case double-suction UL Listed FM Approved mounted on a common base with and flexibly coupled to a diesel engine Pump sized for rated capacity and head Also must be capable of producing 150% rated flow at not less than 65% rated head and not to exceed 140% rated head at a shutoff or no-flow condition Diesel Engine UL Listed or FM Approved diesel engine adequately sized so as to not overload at any point on the pump hydraulic curve Consideration must be given and de-rates applied based on job site elevation and ambient temperature Engines must be specifically designed for fire protection service Coupling Flexible type sized to transmit the horsepower requirements of the pump Coupling shall be furnished with an OSHA-design coupling guard Base Fabricated steel design base capable of adequately supporting the weight of the pump and driver After pump has been fully piped and accurately aligned with the engine the base should be fully grouted into place Controller Diesel engine controller starts the engine automatically on a loss of system pressure System pressure is monitored via a sensing line from the system side of the check valve Controller can also be manually started Controllers are UL Listed and FM Approved specifically for fire pump service Standard Pump Accessories Accessories furnished with the fire pump system include suction and discharge gauges and automatic air release valve Other accessories commonly furnished as part of the fire pump package include hose valve manifold with hose valves caps and chains flowmeter main relief valve and enclosed waste cone ball drip valve eccentric suction reducer concentric discharge increaser Standard Engine Accessories Accessories furnished with the diesel engine include engine starting batteries battery rack battery cables engine exhaust flexible connector and silencer Jockey Pump Jockey pump keeps pressure in the system to prevent the main fire pump from operating to maintain system pressure Jockey pumps are generally a few gallons per minute sized to overcome small system leaks and typically sized for 10 PSI greater than the rated pressure of the main fire pump Jockey pumps are not required to be UL Listed or FM Approved Jockey Pump Controller Starts the jockey pump across the line by sensing the system pressure via a sensing line from the system side of the check valve This sensing line must be independent from the main fire pump controller sensing line Controller is sized per the jockey pump motor horsepower and voltage Jockey pump controllers are UL Listed specifically for this service HORIZONTAL SPLIT CASE FIRE PUMP SYSTEM ELECTRIC MOTOR DRIVEN Isolation Gate Valve (suction) Compound Suction Gauge Horizontal Split Case Fire Pump Electric Motor Driven Automatic Air Release Valve Casing Relief Valve Discharge Pressure Gauge Low Suction Pressure Shutoff Valve Fire Pump Controller System Check Valve Jockey Pump Controller Jockey Pump Isolation Valves Ball Drip Valve Test Valve Manifold with Hose Valves Caps & Chains Pump Horizontal split case double-suction UL Listed FM Approved mounted on a common base with and flexibly coupled to an electric motor Pump sized for rated capacity and head Also must be capable of producing 150% rated flow at not less than 65% rated head and not to exceed 140% rated head at a shutoff or no-flow condition Electric Motor UL Listed or FM Approved motor sized so as to not overload at any point on the pump hydraulic curve as per NFPA #20 Motors are open-drip proof type with a 1.15 service factor wound for the correct voltage Motor to be compatible with the type of controller (i.e., starting characteristics) Coupling Flexible type, sized to transmit the horsepower requirements of the pump Coupling shall be furnished with an OSHA-design coupling guard Base Fabricated steel design base capable of adequately supporting the weight of the pump and driver After pump has been fully piped and accurately aligned with the motor the base should be fully grouted into place Controller Electric motor controller starts the motor automatically on a loss of system pressure System pressure is monitored via a sensing line from the system side of the check valve Controller can also be manually started The type of motor starting and therefore the type of controller varies depending upon the specifics of the application Common types of controllers include across-the-line primary resistor part-winding wye-delta auto-transformer and soft start Controllers are UL Listed and FM Approved specifically for fire pump service Standard Accessories Accessories furnished with the fire pump system include suction and discharge gauges casing relief valve and automatic air release valve Other accessories commonly furnished as part of the fire pump package include hose valve manifold with hose valves caps and chains flowmeter main relief valve and enclosed waste cone ball drip valve eccentric suction reducer concentric discharge increaser Jockey Pump Jockey pump keeps pressure in the system to prevent the main fire pump from operating to maintain system pressure Jockey pumps are generally a few gallons per minute sized to overcome small system leaks and typically sized for 10 PSI greater than the rated pressure of the main fire pump Jockey pumps are not required to be UL Listed or FM Approved Jockey Pump Controller Starts the jockey pump across the line by sensing the system pressure via a sensing line from the system side of the check valve This sensing line must be independent from the main fire pump controller sensing line Controller is sized per the jockey pump motor horsepower and voltage. Jockey pump controllers are UL Listed specifically for this service Across-the-line Primary Resistance Reduced Voltage Part Winding APPROVED CONTROLLER STARTING METHODS Wye-Delta Open-Transition Wye-Delta Closed-Transition Auto Transformer Reduced Voltage Soft Start/Stop Long established as a leading fire pump manufacturer Fairbanks Morse Pump offers a broad range of horizontal split case vertical in-line and vertical turbine designs over a wide range of rated capacities and pressures…pumps for every fire pump application Split case and vertical turbine pumps have the option of being driven via either an electric motor or diesel engine, and are furnished as a complete package with controller jockey pump and its controller as well as standard fire pump system accessories Units are Underwriters Laboratories Listed and Factory Mutual Approved specifically for fire pump service continually meeting their stringent inspection, testing and record-keeping standards. Split case rated capacities range from 250 GPM through 5000 GPM, vertical in-line rated capacities range from 50 GPM through 750 GPM, and vertical turbine fire pumps cover 250 GPM through 4500 GPM, all with a wide range of rated pressures The Fairbanks Morse Pump sales family includes highly qualified distributors and representatives well versed in fire pump systems, who provide prompt and accurate quotations, submittals and acceptance testing as required. These sales professionals stand ready to address and meet your fire pump needs and are backed by many years of factory knowledge and experience Pump Features Bronze impeller keyed to shaft Horizontal split case, cast iron Clockwise or counterclockwise rotation (electric only) Casing wear rings Renewable shaft sleeves Grease lubricated long life bearings Packed stuffing box VERTICAL IN-LINE Pump Features Bronze impeller keyed to shaft One-piece, in-line casting Clockwise rotation Casing wear ring Renewable shaft sleeve Integral vertical drip-proof motor Packed stuffing box VERTICAL TURBINE Pump Features Bronze impellers Cast iron bowl (multi-stage) Stainless steel bowl shaft Carbon steel open lineshaft Steel column pipe Cast iron or fabricated steel discharge heads Brass suction strainer Packed stuffing box PACKAGED FIRE PUMP SYSTEMS When the application calls for a completely packaged fire pump system Fairbanks Morse Pump has the capability to meet these requirements Systems include the pump driver controller jockey pump and jockey pump controller all mounted on a common base Controller is pre-wired to the driver sensing lines are pre-piped from the controllers to the system side of the check valve and suction and discharge piping is piped to the edge of the common base. Isolation valves check valve and test header piping (and/or flowmeter piping) can be supplied as required For diesel engine driven units the package would also include the mounting of the fuel tank piping of fuel lines to the engine and connection of batteries to the engine Should your requirements include the packaged fire pump system to include an enclosure Fairbanks Morse Pump can provide the protective structure to house the system Packaged systems can be designed for use with horizontal split case vertical turbine or vertical in-line pump designs

4 thoughts on “FIRE PUMP

  1. Salam

    Perkenalkan:
    Saya sales engineering di PT. Sumatera Ega Mekinka Medan
    Suplayer:

    Blackmer Pump
    Torishima Pump
    Jesco Doosing Pump
    Griswold pump,
    Selwood pump
    Chesterton (Mechanical Seal, Gasket & Gland packing),
    Goerge Fitcher (#GF#) Piping & assesories,
    TYCO HDPE Piping & assesories (plus Joint Machining),
    Blackmer LPG compressor,
    Chesterton (Spiral Track & Inpro seal),
    Chesterton Technical Product
    Chemplant agitator,
    Hiller decanter &
    Korting vacuum system
    SIHI LPG Multistage Pump

    PRODUK PT. SUMATERA EGA MEKINKA UNTUK PABRIK KELAPA SAWIT

    1. POMPA
    – Blackmer System One Centrifugal Pump
    – Blackmer Sliding Vane Pump
    – Blackmer Magnum Vortec Centrifugal Pump
    – Torishima ETA-N Centrifugal Pump
    – Torishima ETA-CH Centrifugal Pump
    – Jesco Doosing Pump
    – Torishima Multistage Pump
    – Selwood Slurry Pump
    – Griswold Centrifugal Pump

    2. VACUM SYSTEM
    – Korting Steam Ejector

    3. PIPA & ASSESORIES
    – George Fitcher (#GF#) Piping & Assesories
    – Tyco Piping, Assesories & Joint Machine

    4. SENSOR
    – George Fitcher (#GF#) Sensor

    5. MIXER AGITATOR
    – Chemplant Portable Mixer Agitator
    – Chemplant Side Entry Mixer Agitator

    6. DECANTER
    – Hiller Decanter

    APLIKASI PRODUK PT. SUMATERA EGA MEKINKA DI PABRIK KELAPA SAWIT

    1. PEMURNIAN AIR PENGOLAHAN DAN AIR UMPAN BOILER
    – Water Treatment Plant
    • Raw Water Pump : Torishima ETA-N, ETA-CH & Multistage Pump
    • External Doosing Pump : Jesco Doosing Pump
    • Booster Pump : Torishima ETA-N, ETA-CH Pump
    • Domestic Pump : Torishima ETA-N, ETA-CH Pump
    • External Water Cooler Pump : Torishima ETA-CH Pump
    • Instalasi Pemipaan : Tyco Piping & Assesories
    • Mixer Agitator : Chemplant Portable Mixer Agitator

    – Demineralizing Plant
    • Boiler Feed Pump : Torishima Multistage Pump
    • Daerator Feed Pump : Torishima ETA-N, ETA-CH Pump
    • Cation Pump : Torishima ETA-N, ETA-CH Pump
    • Anion Pump : Torishima ETA-N, ETA-CH Pump
    • Internal Doosing Pump : Jesco Doosing Pump
    • Instalasi Pemipaan & Sensor : George Fitcher (#GF#) Piping
    • Mixer Agitator : Chemplant Portable Mixer Agitator

    – Clarification Stasiun
    • Hot Well Water Pump : Torishima ETA-N, ETA-CH Pump

    2. PEMBANGKIT TENAGA PABRIK KELAPA SAWIT
    – Turbin
    • Diesel Pump : Blackmer System One Centrifugal Pump

    3. PROSES PENGOLAHAN KELAPA SAWIT
    – Sterilizer Stasiun
    • Condensate Pit Pump to Recovery Tank : Blackmer System One Centrifugal Pump

    4. PROSES PEMURNIAN MINYAK KELAPA SAWIT
    – Clarification Stasiun
    • Crude Oil Pump : Blackmer Magnum Vortec Centrifugal Pump
    • Sludge Oil Pump : Blackmer System One Centrifugal Pump
    • Reclaimed Oil Pump : Blackmer System One Centrifugal Pump
    • Condensate & Sludge Pump to Recovery Tank: Blackmer System One Centrifugal Pump
    • Fat Pit Oil Pump to Continuous Setling Tank: Blackmer System One Centrifugal Pump
    • Oil Transfer : Blackmer System One Centrifugal Pump
    • Decanter : Hiller Decanter

    5. PENYIMPANAN MINYAK KELAPA SAWIT
    – Palm Oil Storage Tank
    • Despacth Oil Tank : Blackmer System One Centrifugal Pump
    : Blackmer Sliding Vane Pump
    • Storage Tank : Chemplant Site Entry Mixer Agitator

    – Kernel Recovery Stasiun
    • Hydro Cyclone Pump : Blackmer Magnum Vortec Centrifugal Pump
    • Claybath Separator Pump : Blackmer Magnum Vortec Centrifugal Pump

    6. PENGERINGAN MINYAK : Korting Steam Ejector

    7. PENGOLAHAN LIMBAH
    – Kolam Limbah
    • Effluent Pond Pump : Blackmer System One Centrifugal Pump
    • Land Aplication : Selwood Slurry Pump
    : Blackmer System One Centrigugal Pump
    • Composting : Blackmer System One Centrigugal Pump
    • Instalasi Pemipaan : George Fitcher (#GF#) Piping & Assesories
    : Tyco Piping & Assesories
    Thanks

    Kind Regards,
    Inganta (081375650285)
    Sales Engineering

    PT. SUMATERA EGA MEKINKA
    KIM II Medan Industrial Park
    JL. Pulau Bawean I Blok A2
    Medan 20371 – Indonesia
    Telp. : +62-61-6871818
    Fax. : +62-61-6871819
    Email : ing.tarigan@egamekinkamdn.com

  2. Salam kenal pak bahtiar.
    Kalau boleh, saya minta hp nya pak bahtiar. kebetulan saya ingin discuss soal fire pump project. tks

    email saja pak
    karena hape saya buat mobil-mobilan anak saya … hiks :(
    email : bahtiar@gmail.com

  3. Pak Bahtiar, bisa dibantu memberi info tentang positif suction dan negatif suction, serta penggunaan pompa horisontal apakah hanya untuk positif suction saja sesuai dengan NFPA 20

    Baik Ibu Melianus,

    Positive Suction adalah kondisi dimana baling-baling pompa berada di bawah permukaan air, sehingga ketika pompa dihidupkan tinggal mendorong air saja.

    Negative Suction adalah kondisi dimana baling-baling pompa berada di atas permukaan air, sehingga ketika pompa dihidupkan bukan mendorong air tapi menyedot udara.

    NFPA 20, pompa horisontal tidak hanya dipakai untuk Positive Suction tapi juga bisa untuk Negative Suction, caranya pompa horisontal dipasang di samping dinding reservoir dengan kedalaman di bawah permukaan air reservoir tersebut. Sehingga ketinggiar air reservoir memberikan keuntungan tenaga potensial untuk menggerakkan baling-baling pompa bila sewaktu-waktu dihidupkan.

Berikan Balasan

Isikan data di bawah atau klik salah satu ikon untuk log in:

Logo WordPress.com

You are commenting using your WordPress.com account. Logout / Ubah )

Gambar Twitter

You are commenting using your Twitter account. Logout / Ubah )

Foto Facebook

You are commenting using your Facebook account. Logout / Ubah )

Foto Google+

You are commenting using your Google+ account. Logout / Ubah )

Connecting to %s